Projects

Air Filtration & Particulate Sampling System with Real-Time Telemetry Dashboard

A custom-engineered air-filtration and particulate sampling hardware rig equipped with an automated serial telemetry Windows Desktop application for real-time multi-sensor tracking, flow monitoring, and tare calibration.

Air-Filtration_1
Air-Filtration_2

Air Filtration & Particulate Sampling Telemetry System

A custom hardware-software co-designed air filtration system built to enable real-time particulate sampling, multi-sensor calibration, automated testing, and telemetry tracking.

The project bridges industrial physical hardware with a dedicated C# desktop interface, capturing 20 distinct environmental and pneumatic variables across dual-stage (upstream/downstream) filtration paths.


🛠️ System Overview

The physical rig consists of a dual-chamber air intake and particulate filtration testing assembly mounted on a workbench:

  • Upstream & Downstream Sensor Nodes: Real-time monitoring of PM1.0, PM2.5, PM4.0, PM10.0, Humidity, Temperature, VOCs, and NOx on both sides of the filter.
  • Pneumatics & Flow Control: Embedded Differential Pressure, Flow Rate, and dual pressure transducers (P1, P2) tied to electronically switched solenoids/valves and an extraction fan.
  • Automated Airflow Pipeline: Software-orchestrated cleaning, automated zero-offset (tare) calibration, pre-sampling stabilization, and active multi-stage sampling.

💻 Software Architecture & Telemetry Dashboard

The desktop application provides a robust control center for the filtration rig:

Key Features

  • WMI Hardware Discovery: Automatic detection of COM ports with hardware descriptive metadata.
  • 20-Channel Real-Time Plotting: Fast-line visualizer comparing raw vs. calibrated metrics (PM, Temp, RH, VOCs, NOx, Flow, DP).
  • Automated Workflow Engine:
    • Cleaning & Tare Mode: Flushes chambers and computes baseline zero-offsets over a running average.
    • Preparation & Sampling: Sequences fan and pneumatic valves automatically, ensuring laminar flow before capturing filtration runs.
    • Manual Test Mode: Direct valve & fan manual toggles with active safety interlocks.
  • Data Persistence: Full 41-column CSV export/import and high-resolution chart rendering.

📊 Serial Communication Protocol

  • UART Configuration: 115,200 baud, 8N1, 1000 ms timeout.
  • Telemetry Stream: 21-token comma-separated telemetry packet at 1 Hz, monitoring upstream and downstream states across particulate sizes (PM1.0 to PM10.0), gases, and flow metrics.